34 research outputs found

    Armageddon: The Inevitable Death of Nuclear Power and Whether New York State Has the Legal Authority to Keep It on Life Support

    Get PDF
    This Note seeks to make the argument for New York’s ZEC program as a legitimate exercise of state power. Part I provides context—the history of nuclear power, the rise and fall in the incidence of nuclear power projects, and why such investments are failing. Part II then provides an overview of the CES and the ZEC program contained therein. In Part III, the legal challenges filed in response to Tier 3 are discussed, as well as the Illinois case which parallels the conventional generator challenge in New York. Part III will also discuss relevant legal precedent the cases concern, namely the recent United States Supreme Court case, Hughes v. Talen Energy Marketing, LLC. Part IV analyzes federal preemption to the extent it affects the New York program. This analysis mirrors—and in some areas, expands upon—the district court’s findings regarding New York’s program. Further, it compares similar crediting mechanisms currently used across the United States and other analogs demonstrating that, although federal preemption appears to control, there is significant room for the states to regulate. This Note ultimately concludes in Part V that the ZEC program is likely a legitimate exercise of state power, despite incidental effects it may have on related federal regulation

    Low loss coatings for the VIRGO large mirrors

    Get PDF
    présentée par L. PinardThe goal of the VIRGO program is to build a giant Michelson type interferometer (3 kilometer long arms) to detect gravitational waves. Large optical components (350 mm in diameter), having extremely low loss at 1064 nm, are needed. Today, the Ion beam Sputtering is the only deposition technique able to produce optical components with such performances. Consequently, a large ion beam sputtering deposition system was built to coat large optics up to 700 mm in diameter. The performances of this coater are described in term of layer uniformity on large scale and optical losses (absorption and scattering characterization). The VIRGO interferometer needs six main mirrors. The first set was ready in June 2002 and its installation is in progress on the VIRGO site (Italy). The optical performances of this first set are discussed. The requirements at 1064 nm are all satisfied. Indeed, the absorption level is close to 1 ppm (part per million), the scattering is lower than 5 ppm and the R.M.S. wavefront of these optics is lower than 8 nm on 150 mm in diameter. Finally, some solutions are proposed to further improve these performances, especially the absorption level (lower than 0.1 ppm) and the mechanical quality factor Q of the mirrors (thermal noise reduction)

    The Virgo data acquisition system

    Get PDF
    International audienc

    The gravitational wave detector VIRGO

    Get PDF
    International audienc

    Choosing outcome assessment tools in haemophilia care and research: a multidisciplinary perspective

    No full text
    Introduction: The implementation of early long-term, regular clotting factor concentrate (CFC) replacement therapy (‘prophylaxis’) has made it possible to offer boys with haemophilia a near normal life. Many different regimens have reported favourable results, but the optimum treatment regimens have not been established and the cost of prophylaxis is very high. Both for optimizing treatment and reimbursement issues, there is a need to provide objective evidence of both short- and long-term results and benefits of prophylactic regimens. Aims: This report presents a critical review of outcome measures for use in the assessment of musculoskeletal health in persons with haemophilia according to the International Classification of Functioning, Disability and Health (ICF). This framework considers structural and functional changes, activities and participation in a context of both personal and environmental factors. Methods: Results were generated by a combination of a critical review of available literature plus expert opinion derived from a two day consensus conference between 48 health care experts from different disciplines involved in haemophilia assessment and care. Outcome tools used in haemophilia were reviewed for reliability and validity in different patient groups and for resources required. Results and conclusion: Recommendations for choice of outcome tools were made according to the ICF domains, economic setting, and reason for use (clinical or research). The next step will be to identify a ‘core’ set of outcome measures for use in clinical care or studies evaluating treatment

    Low-loss coatings for the VIRGO large mirrors

    No full text
    corecore